VMware vCenter Got an Emergency Patch After Mandiant Found a Login Bypass Used Since September
Broadcom patched CVE-2026-123890 in vCenter on November 19, CVSS 9.8, no workaround. Mandiant says ARMORY CASTLE used it as a zero-day in early September to take [email protected].
Broadcom shipped an emergency vCenter patch on November 19. Mandiant says the hole it closes had already been used as a zero-day since early September.
VMSA-2026-0009 rates CVE-2026-123890 Critical, CVSS 9.8, with no workaround. VMware vCenter's Directory Service can be reached by anyone who has network access to the appliance. A successful attack bypasses authentication and gets unauthorized access. Broadcom credits Mandiant for the report. The advisory itself does not say the bug was exploited in the wild.
Google Threat Intelligence Group and Mandiant do. They call it an unauthenticated Secure Remote Password session-key leak over DCE/RPC. Exploitation, they write, creates an authenticated session as [email protected]. From there the attacker can run commands and pull files, including the directory database, through the vmdird RPC interface.
Two months of quiet
The group Mandiant tracks as ARMORY CASTLE, formerly UNC5221, a suspected PRC-nexus actor, used a custom Golang tool named BONESAW against an internal vCenter in early September. Mandiant says the same campaign started on a BeyondTrust Remote Support appliance, a zero-day it documented in October, then moved to an internal Linux box with no endpoint detection, then went hunting for VMware.
BONESAW, in Mandiant's account, created a Single Sign-On administrator, copied the Lightning Memory-Mapped directory database, and can extract the SAML signing key used by vCenter's token service. A second tool, SAWSNAKE, is built to forge those tokens. After that, the path is the virtualization stack: ESXi hosts, then guest disks, including Windows Active Directory files.
ARMORY CASTLE is the same shop Cyberpresso has watched on Citrix NetScaler and other edge gear. Two zero-days in one chain is the part Mandiant wants defenders to notice. Broadcom's bulletin still reads like a patch Tuesday.
What actually patches
Fixed vCenter builds are 9.1.1.0200, 9.0.2.0200, and 8.0 U3m. Cloud Foundation 5.x takes 5.2.5. Telco Cloud Platform and Telco Cloud Infrastructure point at KB463116. vCenter 7.0 is listed as affected, with the fix held behind an extended-support call to Broadcom. Mandiant says BONESAW works against 7.x and 8.x appliances.
The same advisory patches four other bugs in SDDC Manager and VMware Tools for Windows, none of them the reason this is an emergency. There is no official workaround. Network restrictions help only if vCenter is not already reachable from the place an attacker landed.
vCenter is the control plane for the VMs. Once it is an administrator session, the rest of the farm is a file copy. Broadcom told customers to install the patches as soon as possible. Mandiant's timeline says that advice is two months late.
Some offers on this page may be paid placements or contain affiliate links.
Cyberpresso: daily cyber & AI brief
Free daily newsletter, read in 5 minutes.
Subscribe free